GigaLog

GigaLog is a data logger for up to 2 Gbytes of data using CompactFlash memory cards.
With GigaLog any embedded system can log its data easily, for a very long period, and readable by a PC.

GigaLog automatically recognizes CompactFlash memory cards, their size, formats the disk, creates a MSDOS compatible file system, and creates files to store the data into it. When switching power on, or changing the memory card, new data will be appended to the files. Stored data can be read on a PC using a simple CompactFlash adapter. The memory card appears as a removable disk to the PC. All data from the RS232 is in a single file, analog data in another file on the disk.

Storing data from 8 analog or digital inputs
Gigalog E
has 8 inputs. Gigalog F has 16 inputs. Each input can be configured as analog, digital, or counter. Gigalog samples these inputs regularly and stores them on the disk in a file.

Storing incoming data from RS232
All data coming in from the serial RS232 interface will be stored on the disk in a file. A data frame from the RS232 is any consecutive data until there is a gap of at least 0.5 seconds. GigaLog can be configured to add a time stamp (yyyy:mm:dd hh:mm:ss) in front and/or at the end of a data frame.

Remote Control (Gigalog F)
GigaLog F
can be completely controlled by a modem: Verify state, change configuration, disk handling, upload logged data. Each input has a min and a max threshold. When the input violates a threshold, an alarm occurs. An alarm may toggle a relay, write a message into a disk file, call a centre using a phone, or send an SMS, using a GSM modem. You may define a command macro, that calls a centre, or sends an SMS each hour, day, or once a week.

A LED on the board shows that GigaLog is storing data on the disk. When the LED is off, data is safe, you can remove the CompactFlash card.

GigaLog is available as board or in a housing to be mounted on a DIN rail.
GigaLog includes all tools to write your own firmware: C compiler, debugger, firmware source, documentation.

* Configurable
* Stores data from analog or digital inputs

o Gigalog E: 8 inputs 0-2.56V or 0-20 mA, 10 bit resolution
o Gigalog F: 16 inputs 0-2.5V or 0-20 mA, 16 bit resolution
o Gigalog F: Each input can read a thermocouple type K (50°C to 1300 °C) including cold junction compensation
o Gigalog F: Each input can read a PT100 (-200°C to +850 °C)
o Digital inputs, 0/5V
o Counter up to 500 Hz
o Input options

+ RC filter
+ Voltage divider for higher voltages

o Sample rates from 1 millisecond to 24 hours

* Stores incoming data from Rs232

o Baud rates from 300 to 115200 baud
o High speed, no need for flow control
o Optional timestamp at the beginning or the end of a frame.
o Supports data from GPS

* Remote Control (GigaLog F)

o By modem: Verify state, change configuration, disk handling, upload logged data.
o By SMS, GSM modem: request state.
o Alarm: Toggle relay, store message in disk file, call centre using a modem, send SMS using a GSM modem.
o Each hour, day, once a week: call centre, send SMS
o 2 solid state relays (60V, 150 mA)

* Msdos/ Windows compatible file system
* No need for Open or Close operations
* Very easy to use
* Power supply 7..12 V unregulated or 5V±5%, typ 50mA. 100x86x25mm or 105x90x60 mm
* Power reduction mode: 50 µA

GigaLog stores 8 analog inputs: 2003:07:24 11:56:30:315 109 789 833 1020 911
 Incoming data from Rs232:  machine error 51
GigaLog adds optional timestamp 2003:07:24 11:56:30 machine error 51


When the data frames follows a certain format, PC utility program Gigadata (included) can be used to visualize the data on the PC.

 

GigaLog completely programmable in C
To customise the board, you may write your own firmware in C, and download it into GigaLog.
Delivered with the board: IDE under Windows, C compiler, library for the board, debugger, firmware examples.

GigaLog manual

Gigalog712.exe Load GigaLog Version 7.12. Last version of the complete softaware (GigaTerm, GigaData, Bord firmware) and manual

GigaLog end FlashLog

GigaLog E

GigaLog F

Caviar B, Caviar C

Datalogger

Datalogger + Remote Control

Embedded System With Data Storage

Analogue inputs

8 16 8
ADC resolution 10 bit 16 bit 10 bit

Disk Compact Flash

2 Giga 2 Giga 2 Giga

Integrated Firmware

+ + +
Configuration easy, terminal easy, terminal easy, terminal
Samples >= 1ms >= 1ms

-

Counter inputs

8 x 500 Hz

16 x 500 Hz

-

Storing rs232 115200 baud 115200 baud 115200 baud

Programmable

in C in C in C
Display LCD + + +
Storing GPS + + +
2. port Rs232 for GPS 100x86 100x86 100x86
Other inputs

-

-

8 opto-coupled, digitals
 Other outputs

 -

2 solid state relay  8 relays, digital and analogue outputs
 Others

 -

-

  Keypad 4x4
 Low power mode   battery battery

 -

Format 100x86 100x86

160x100 mm Euro

Housing for Din rail for Din rail for Din rail
 Analogue inputs

 

0..2v5 or 0..20 mA

RC filter

Voltage divider

0..2v5 or 0..20 mA
RC filter
Voltage divider

 

0..2v5 or 0..20 mA

RC filter

Voltage divider (2 inputs)

 Analogue inputs with instrumentation amplifier

 

2 (option)

-

 

2 (option)

Other needs? We can do an individual adaption for you


| GigaLog | | Prices |


Page up-dated at January 18 2008


GRIFO®
Via dell'Artigiano, 8/6
40016 San Giorgio di Piano
Bologna ITALY

Tel: +39 051 892.052 (4 lines)
FAX: +39 051 893.661


homeHome Index Categorical Index CPU Tables